CO-TRK (Analog CO Trunk)
Issue 1 May 2002
8-471555-233-143
Table 8-189. Test #36 Port Audit Update Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1006 ABORT The port has been placed out of service, perhaps by craft busyout.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is active, wait until it is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
2100 ABORT System resources required to run this test were not available.
1. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS This test passed. Translation information was successfully updated on the
circuit pack. User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external wiring. If the trunk is
busied out, the test will not run, but will return PASS. To verify that the trunk is
in-service:
1. Enter status trunk to verify that the trunk is in-service. If the trunk is
in-service, no further action is necessary. If the trunk is out-of-service,
continue to step 2.
2. Enter release trunk command to put trunk back into in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the boards translations are correct. Translate the board, if
necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Continued on next page