1947 ABORT Noise with tone self check failed.
1. Test the TN771 circuit packs.
2000 ABORT The test timed out while waiting for a response from the TN771 circuit pack.
1. Retry the command at 1-minute intervals up to 5 times.
2012 ABORT An internal software error occurred.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABORT The test call could not be established, but an explanation is unavailable.
1. Retry the command at 1-minute intervals up to 5 times.
2056 ABORT An error occurred while trying to obtain results from the TN771 circuit pack.
1. Test the TN771 circuit packs.
FAIL Measured transmission performance was in the unacceptable range as
administered on the trunk group form. Retrieve a measurement report via the
list testcalls command. Make sure that ATMS thresholds are set properly on
page 4 of the trunk group form. Besides the facility, test failures can be caused
by faulty test lines or switch paths. If the measurements point to a facility
problem, report the results to the trunk vendor.
8000 FAIL Measured transmission performance was in the marginal range as
administered on the trunk group form. This generally means that the trunk is
usable but has an undesirable amount of noise or loss. If the user does not
report unacceptable effects, it may not be necessary to take any action.
Retrieve a measurement report via the list testcalls command. Make sure
that ATMS thresholds are set properly on page 4 of the trunk group form.
Table 8-190. Test #844-848 Transmission Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page

Table of Contents