Maintenance-Object Repair Procedures
555-233-143
8-490 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate errors.
b. Indicates the circuit pack has been removed or has been insane for more
than 11-minutes. To clear the error, reseat or replace the circuit pack.
c. Error type 769 indicates that the data line circuit pack found an error in the
transmit/receive circuitry of an administered data line when the circuit pack
was inserted. Perform the following:
1. Enter busyout board UUCSS for the circuit pack on which the port
resides.
2. Enter reset board UUCSS. Check the Error Log to determine
whether Error Type #769 is logged again for DAT-LINE. Make sure
that the Active Alarms Only field is set to n.
If Error Type #769 reappears, replace the data line circuit pack. If
not, proceed to step 3.
3. Enter release board UUCSS.
Table 8-197. Data Line Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 Digital Looparound
test (#171)
MINOR ON test port UUCSSpp s r 2
15(a) Any Audit Update test
(#36)
18 0 Busyout port
UUCSSpp
WARNING OFF rel port UUCSSpp
130 (b) None WARNING ON test port UUCSSpp sh
257 Conference Circuit
test (#7)
MINOR ON test port UUCSSpp l r 2
513 NPE Crosstalk test
(#6)
MINOR ON test port UUCSSpp l r 2
769(c) 40983 None