Maintenance-Object Repair Procedures
555-233-143
8-492 Issue 1 May 2002
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. Resolve any TDM-BUS errors.
2. If the system is not handling heavy traffic, retry the command at 1-minute
intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV and TONE-PT errors.
2. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004 ABORT The port was in use on a valid call.
1. Determine whether the port is available for testing (status data-module).
2. When available, retry the command at 1-minute intervals up to 5 times.
1020 ABORT An existing Error Type 769 on this port prevented the test from running.
1. Follow the procedures for Error Type 769.
2000 ABORT Response to the test command was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port was transmitting in error, which can cause noisy
and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
1. Investigate user-reported troubles on this port using other port tests and
examining the ADU, external wiring, and customer equipment.
Table 8-198. Test #6 NPE Crosstalk Test Continued
Error
Code
Tes t
Result Description / Recommendation