Maintenance-Object Repair Procedures
555-233-143
8-494 Issue 1 May 2002
Audit Update Test (#36)
This audit verifies that the hardware state of the data line is consistent with the
system translations. The audit queries the port for the switchhook state, the
software state is updated according to the returned value. Also, the audit data line
options down to the port.
Digital Loop-Around Test (#171)
The Digital Looparound test checks the data line ports ability to transmit and
receive data on the TDM Bus. Data is sent through an available
Maintenance/Test digital port over the TDM Bus, internally looped through the
data line port back onto the TDM Bus, and received again by the same
Maintenance/Test digital port.
Note that only one of the two digital ports on a Maintenance/Test circuit pack is
used for this test, and that port must be the first such port; such as port 02. If
port 02 is in use, out-of-service, or not present, the test aborts. This test may fail if
the Maintenance/Test digital port used by the test is not functioning properly. If
there are any M/T-DIG errors in the Error Log, see ‘‘M/T-BD (Maintenance/Test
Circuit Pack)’’ clear them first. This test will pass regardless of any customer
equipment that may be connected to the port, as long as the equipment is not
using the port.
Table 8-200. Test #36 Audit Update Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate the problem if the test continues to abort.
1006 ABORT An existing Error Type #769 on this port prevented the test from running.
1. Follow the procedure following the Error Log Table for Error Type #769.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
ABORT Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
7 FAIL Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
PASS The hardware port state is consistent with the software state. Investigate
user-reported troubles on this port using other port tests and examining the
ADU, external wiring, and customer equipment.