DC-POWER (Single-Carrier Cabinet Environment)
Issue 1 May 2002
8-501555-233-143
Table 8-203. Test #79 Single-Carrier Cabinet Power Query Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with a 2000 error code, check for and
resolve every MAINT (Maintenance circuit pack) error. Then, repeat the
test.
3. If the test still aborts with this error code, escalate the problem.
2029,
2319,
2320,
2500
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 FAIL There is currently a problem with the environment of the power system.
1. The power supply to any one of the carriers may have been lost.
a. Verify, and if necessary restore, AC power at the wall outlet for each
carrier.
b. Rerun the test. If the test still fails, proceed to step 2.
2. One of the WP-91153 or 676-B power units for one of the carriers could be
defective.
a. If a WP-91153 or 676-B power unit does not have its yellow status LED
on, then replace the power unit (procedure in Chapter 4, ‘‘Alarms,
Errors, and Troubleshooting’’).
b. Rerun the test. If the test still fails, proceed with step 3.
3. The PNs MAINT (Maintenance circuit pack) could be incorrectly reporting
this error. Resolve every alarm on these MOs, and rerun the test. There
are failures that can occur on the PNs Maintenance circuit pack that will
not be detected by their respective maintenance, but that will cause many,
if not all, environment tests to fail. If more than two environment tests are
failing, the suspect circuit pack, depending on the system configuration,
should be replaced and the test rerun. If the test still fails, follow normal
escalation procedures.
PASS The PNs MAINT (Maintenance circuit pack) has reported no problem with the
power.
Continued on next page