DID-DS1 (Direct Inward Dial Trunk)
Issue 1 May 2002
8-507555-233-143
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below. By
clearing error codes associated with the NPE Crosstalk test, for example, you
may also clear errors generated from other tests in the testing sequence.
NPE Crosstalk Test (#6)
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected
time slot and never crosses over to time slots reserved for other connections. If
the NPE is not working correctly, 1-way and noisy connections may be observed.
This test is usually only part of a port’s long test sequence and executes in about
20 to 30 seconds.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6) X ND
Conference Circuit test (#7) X ND
Port Audit and Update test (#36) X X ND
Table 8-205. Test #6 NPE Crosstalk Test
Error
Code
Tes t
Result Description / Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required for this test are not available.
The port may be busy with a valid call.
1. Use display port UUCSSpp to determine the trunk group/ member
number of the port. Use the status trunk command to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is active but the port is idle (no calls), check the error log
for Error Type #1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1001 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page