DID-TRK (Direct Inward Dial Trunk)
Issue 1 May 2002
8-529555-233-143
PASS This test passed. Translation information was successfully updated on the
circuit pack.
1. If signaling troubles are reported (Error Types 1, 257, or 513), verify
translation for this port.
2. Refer problem to the CO.
0NO
BOARD
The test could not relate the internal ID to the port.
1. Verify that the board’s translations are correct. Translate the board if
necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command.
This should re-establish the linkage between the internal ID and the port.