DIG-IP-STN (Digital IP Station)
Issue 1 May 2002
8-535555-233-143
Digital Terminal Lamp Update (#16)
This test updates internal lamp states that can or cannot be shown on the actual
PC graphical user interface. The lamp updates run only if the station is in-service.
The status of the station is checked and the lamp updates are blocked from taking
place if the station is not in the in-service state. This test does not affect the
status of the Message Waiting lamp.
Table 8-215. Test #1373 Signaling Path PING Test
Error
Code
Tes t
Result Description / Recommendation
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
1003 FAIL Ping to the destination failed.
1. Retry the command at 1-minute intervals up to 3 times.
2. Investigate any errors of the C-LAN’s Ethernet port.
1007 FAIL The system could not PING the registered endpoint via the C-LAN.
1. Verify that at least one destination reachable through this port. PING this
destination (ping ip-address xxx.xxx.xxx.xxx).
2. If a PING to any destination is successful through this port, the link is up.
3. If PING to every destination fails, test the C-LAN port (test port UUCSSpp
short), and follow repair procedures for Session Status test (#1286)
failures.
4. If only this station cannot be pinged:
■ Make sure the PC is up.
■ Make sure the PC has a network connection (Ethernet or
dial-up).
■ Check the Ethernet cabling.
PASS The system can successfully send IP packets to the registered endpoint from
the C-LAN.