DIG-IP-STN (Digital IP Station)
Issue 1 May 2002
8-537555-233-143
The terminal returns its configuration information and health information.
The information is checked, and a PASS/ABORT result is provided. If the
result is ABORT, an error is logged in the hardware error log (IP terminal
only)
.
Table 8-217. Test #17 Station (Digital) Audits Test
Error
Code
Tes t
Result Description / Recommendation
1 ABORT Switchhook audit timed out.
2 ABORT ID request fails, health bit returned from voice terminal is bad (IP Terminal
only).
1. Make sure voice terminal is connected, and repeat test.
2. If test fails, replace the voice terminal, and repeat test.
4 ABORT Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals up to 5 times.
5 ABORT Ringer update aborted due to station being in ready-for-service or
out-of-service state.
6 ABORT This port could have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error is present, then release the port via release station extension.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required for this test are not available.
2000 ABORT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
PASS Station Audits passed.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Continued on next page