1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a t for the port).
2. If either list config or display port indicate that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
2000 ABORT Response to the test was not received in the allowable time period.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Station Audits passed. This Digital Port circuit pack is functioning properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Table 8-225. Test #17 Station (Digital) Audits Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page