DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 May 2002
8-567555-233-143
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
■ 1281—Loss of signal
■ 1793—Blue Alarm
■ 2049—Red Alarm
■ 2305—Yellow Alarm
■ 1537—Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining station,
trunk, or external wiring.
Table 8-228. Test #6 NPE Crosstalk Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page