DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 May 2002
8-569555-233-143
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281Loss of signal
1793Blue Alarm
2049Red Alarm
2305Yellow Alarm
1537Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated by using other port tests and by examining
station, trunk, or external wiring.
Table 8-229. Test #7 Conference Circuit Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page