Maintenance-Object Repair Procedures
555-233-143
8-572 Issue 1 May 2002
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
■ 1281—Loss of signal
■ 1793—Blue Alarm
■ 2049—Red Alarm
■ 2305—Yellow Alarm
■ 1537—Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL The trunk cannot be seized for an outgoing call.
1. Verify that the
Trunk Type field on the trunk administration screen form
matches the trunk type administered on far-end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If present, see
‘‘UDS1-BD (UDS1 Interface Circuit Pack)’’ on page 8-1707.
3. Retry the test at 1-minute intervals up to 5 times.
PASS The trunk can be seized for an outgoing call.
Table 8-231. Test #314 DS1 CO Dial Tone Seizure Test — Continued