DS1-BD (DS1 Interface Circuit Pack)
Issue 1 May 2002
8-597555-233-143
NPE Connection Audit Test (#50):
The system sends a message to the on-board microprocessor to update the
network connectivity translation for all the Network Processing Elements (NPEs)
on the circuit pack.
Table 8-241. Test #50 NPE Connection Audit Test
Error
Code
Tes t
Result Description / Recommendation
None,
2100
ABORT System resources required for this test are not available.
1019 ABORT Test already in progress.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS The circuit packs NPEs have been updated with their translation.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the boards translations are correct. Use the add ds1 UUCSS
command to administer the DS1 interface if it is not already administered.
2. If board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
3. Issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Continued on next page