DS1-BD (DS1 Interface Circuit Pack)
Issue 1 May 2002
8-599555-233-143
SAKI Sanity Test (#53)
This test is destructive. This test resets the circuit pack.
PASS Communication with this circuit pack is successful.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the add ds1 UUCSS
command to administer the DS1 interface if it is not already administered.
2. If board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 8-243. Test #53 SAKI Sanity Test
Error
Code
Tes t
Result Description / Recommendation
None ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABORT Wrong circuit pack configuration to run this test. This error applies only to DS1
Interface circuit packs. It means the DS1 Interface circuit pack is providing
timing for the system and, therefore, it cannot be reset without major system
disruptions.
1. If the circuit pack needs to be reset, then set synchronization to another
DS1 Interface circuit pack or to the Tone-Clock circuit and try again. Refer
to “SYNC (Synchronization)”.
Continued on next page
Table 8-242. Test #52 Control Channel Loop-around Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page