DS1-BD (DS1 Interface Circuit Pack)
Issue 1 May 2002
8-609555-233-143
1324 FAIL A non-service-affecting CSU module/T1 sync splitter audit failure was detected
by the TN767E DS1 circuit pack. No ports should be affected. No immediate
action is required. These errors indicate that the CSU module/T1 sync splitter
hardware may have a problem, and that it should be replaced when practical to
avoid further deterioration.
PASS DS1 signal is present and the physical link is healthy. In addition, no Integrated
CSU errors are detected.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the add ds1 UUCSS
command to administer the DS1 interface if it is not already administered.
2. If board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the link between the internal ID and the port.
Table 8-245. Test #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page