Maintenance-Object Repair Procedures
555-233-143
8-692 Issue 1 May 2002
!
WARNING:
The two DS1 CONV boards, TN1654 and TN574, use unique Y cables that
are incompatible with each other.
!
WARNING:
A TN573B (or higher-suffixed) board must be used when connecting a SNI
board to a TN1654 DS1 Converter board.
Steps Comments
Enter list fiber-link Determine the fiber-link number associated with
the two TN574 circuit packs to be upgraded.
Enter busyout fiber-link <fiber #> fiber # represents the fiber-link number associated
with the TN574 DS1 CONV complex that is being
upgraded to a TN1654 DS1 CONV complex.
Enter remove fiber-link <fiber #>
Remove the TN574 DS1 CONV circuit packs
from the system.
Replace the TN574 Y-cables with
appropriate TN1654 Y-cables.
Replace the removed TN574 DS1 CONV
circuit packs with TN1654 DS1 CONV circuit
packs. Prior to installing the TN1654 boards,
review the prior section, TN1654 Board
Configuration Switch Settings.
If a TN1654 DS1 CONV board is connected
to an SNI board, upgrade the SNI to a
TN573B or greater.
Wait for the circuit packs to reset Red and green LEDs will light and then go out.
Enter change circuit-packs <cabinet #>.
Update the form to show that TN1654 boards
are now being used instead of TN574
boards. Also update the connected SNI, if
applicable, to suffix B.
cabinet # represents the cabinet associated with a
DS1 CONV board. The appropriate change
circuit-packs form needs to be updated for both
DS1 CONV boards. Also, if needed, re-add
translations for connected EI boards.
Enter add fiber-link <fiber #> to re-add the
fiber-link using TN1654 DS1 CONV circuit
packs.
fiber # represents the fiber-link number associated
with the TN574 DS1 CONV complex that is being
upgraded to a TN1654 DS1 CONV complex
Enter test alarms long clear for category
exp-intf.
Wait 5 minutes for SNI-BD, FIBER-LK AND
DS1C-BD alarms to clear, or enter clear
firmware-counters a-pnc