EMG-XFER (Emergency Transfer)
Issue 1 May 2002
8-737555-233-143
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests:
Descriptions and Error Codes (Multicarrier)
Always investigate tests in the order presented in the table below. For example,
by clearing error codes associated with the Battery and Battery Charger Query
test (#5), you may also clear errors generated from other tests in the testing
sequence.
Table 8-286. EMG-XFER Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0Any Any Anytest environment UU
1 0 Emergency Transfer query
(#124)
MAJOR ON test environment UU r
3
257 0 Emergency Transfer query
(#124)
WARNING ON test environment UU r
3