ETR-PT (Enhanced Tone Receiver Port)
Issue 1 May 2002
8-759555-233-143
Table 8-297. Test #42 Tone Detection Verification Test
Error
Code
Tes t
Result Description / Recommendation
none ABORT The system was not able to allocate all the resources needed for this test, or
there was an Internal system error.
1 ABORT The system could not allocate all the resources needed to test the tones.
1001 ABORT The system was unable to put the ETR-PT in the appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test connection. This situation
could occur when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM-BUS with the test tdm command.
1. Retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a Tone-Clock for the test connection. This may
be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the TONE-BD or TONE-PT in
the PN where the test aborted.
2. If a new Tone-Clock has been inserted, allow about 1 minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Circuit packs response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2006 ABORT This abort code indicates that the active Tone-Clock circuit pack or a Tone
Detector circuit pack may not be functioning properly.
1. Test the active Tone-Clock circuit pack in the PN with the test tone-clock
UUC command.
2. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1122 FAIL DTMF digits were not detected correctly.
1. Run the short test sequence with the test port UUCSSpp sh r 1
command.
2. If the problem persists, the system is still operating properly but capacity is
reduced. To restore performance to normal, replace the circuit pack with
the defective ETR-PT.