Maintenance-Object Repair Procedures
555-233-143
8-764 Issue 1 May 2002
Figure 8-34. Direct Connect Configuration with Unduplicated PNC
Each PN in a direct-connect configuration must be connected to the other PNs
through a fiber link. Each PN has one EI that functions as an Archangel. This EI
must be connected with fiber to an EI located in the PN with an IPSI. If an EI is
functioning as an Archangel (bus master), its amber LED will be flashing at a rate
of 2 seconds on and 200 ms off.
Figure 8-35 on page 8-765 shows the location of EI circuit packs in a typical
duplicated PNC, direct-connect configuration.
Slot #
Slot #
Slot # Slot #
2
2
2 1 2 1
CABINET 2 CABINET 3
CARRIER A CARRIER A
CABINET 1
CABINET 1
EPN
EPN
E
E
E E E E
I
FIBER LINKS
I
I I I I
PORT CARRIER
PORT CARRIER
PPN
PPN