Maintenance-Object Repair Procedures
555-233-143
8-784 Issue 1 May 2002
j. Error Type 2305 with Aux Data 118—Indicates that the EI circuit pack has
detected slips on the incoming fiber data stream. That is, an PN in a Direct
Connect configuration, or an PN and a Switch Node in a Center Stage
Switch configuration, are not synchronized.
1. Enter display errors and follow the repair procedures for non-slip
errors against any SYNC, TDM-CLK, TONE-BD, DS1 CONV-BD,
EXP-INTF, SNC-BD, and SNI-BD. Non-slip errors are those not
listed below:
2. For slip errors, see ‘‘SYNC (Port-Network Synchronization)’’ on
page 8-1509.
Error Type 2306—Indicates on-board failures related to system timing and
synchronization. Perform the ‘‘Fault Isolation for Fiber Links’’ described in
Chapter 4, ‘‘Alarms, Errors, and Troubleshooting’’.
k. Error Type 2561—Indicates an on-board failure of EI circuitry related to
handling packet data from the fiber interface and from the packet-bus
interface.
1. If this error has generated a minor alarm, the EI circuit pack should
be replaced.
l. Error Type 2817—Indicates an on-board failure of EI circuitry related to
transmission of data to the fiber interface.
1. If this error has generated a minor alarm, the EI circuit pack or
transceiver should be replaced.
m. Perform the following steps for error type 3073:
1. Execute the display errors command and resolve any errors on the
following: PKT-BUS, PKT-INT, PDATA-BD, PGATE-BD, BRI-BD,
BRI-PT, BRI-SET/ASAI, UDS1-BD.
2. Enter the test board UUCSS r3 command for this circuit pack. If
this error continues to appear, replace the EI circuit pack.
Circuit Pack Name Error Log Name
Error Log
Entry for Slips
DS1 Interface DS1-BD 3073 to 3160
Expansion Interface EXP-INTF 2305
SNI SNI-BD 1537
Tone-Clock TDM-CLK 1025
UDS1 Interface UDS1-BD 3073 to 3160
DS1 CONV circuit pack DS1 CONV-BD 3329