EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-801555-233-143
1139 ABORT The packet bus in the PN where this EI board resides has a major alarm
against it. This test needs to use the alarmed PNs packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
alarms.
2. Retry the command.
1141 ABORT The Packet Interface circuit pack is out of service.
1. See ‘‘PKT-INT (Packet Interface)’’.
1144 ABORT The PNs packet bus has a major alarm against it. This test needs to use the
alarmed PNs packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
alarms.
2. Retry the command.
1394 ABORT The EI board is out of service and the test cannot be run. This condition is due
to a change in the EI boards ability to communicate with the EI or SNI circuit
pack on the other end of the fiber.
1. Run Test #237 and check the Error Log for EXP-INTF Error Type 1281. If
Error Type 1281 is present or if Test #237 fails, see repair procedures for
Test #237, in Table 8-303 on page 8-787.
1395 ABORT This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
1407 ABORT This test cannot be run on an EI board that is on the active PNC because it
cannot be busied out. This error code indicates that PNC duplication is
enabled.
1. Attempt to perform a PNC interchange via the reset pnc interchange
command.
2. If the PNC interchange is successful, busyout the original EI circuit pack
via the busyout board UUCSS (address of the original EI board).
3. Retry the command.
2000 ABORT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
Table 8-307. Test #242 Expansion Interface Lightwave Transceiver Looparound
Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page