EXP-PN (Expansion Port Network)
Issue 1 May 2002
8-825555-233-143
Table 8-313. Test #955 PN Cold Restart
Error
Code
Tes t
Result Description / Recommendation
1386 ABORT The system link to this PN is unavailable and cannot be used. This reset
cannot be executed without the link being operational.
1. Refer to SYS-LINK and resolve the link problem.
2100 ABORT Could not allocate the necessary system resources to execute this reset.
2000 ABORT Response to a request made in the internal portion of this reset procedure was
not received within the allowable time period.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS The PN Cold Restart procedure completed successfully.
Continued on next page