EasyManua.ls Logo

Avaya S8700 - Page 1560

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance-Object Repair Procedures
555-233-143
8-838 Issue 1 May 2002
2000 ABORT Response to the test request was not received within the allowable time period.
1. Run the test board UUCSS test separately for each EI endpoint on this
fiber link and follow the procedures in ‘‘EXP-INTF (Expansion Interface
Circuit Pack)’’.
2100 ABORT System resources required to run this test are not available.
1. Run the test board UUCSS test separately for each EI endpoint on this
fiber link and follow the procedures in ‘‘EXP-INTF (Expansion Interface
Circuit Pack)’’.
2500 ABORT Internal system error
1. Run the test board UUCSS test separately for each EI endpoint on this
fiber link and follow the procedures in ‘‘EXP-INTF (Expansion Interface
Circuit Pack)’’.
FAIL EI circuit pack cant frame up to incoming signal. Several fail codes may be
returned depending on which endpoint cant frame up. Error codes 2326,
2327, and 2328 denote Endpoint 1, Endpoint 2, and both endpoints,
respectively.
1. Clear any SYNC and TDM-CLK errors listed in the error log.
2. Run the test board UUCSS test for each EI board on this fiber link and
follow the appropriate repair sequence for any failing tests.
3. If the EI circuit pack fails Test #238 and is in the PN, and the red LEDs are
ON for a large number of circuit packs, then reseat any Tone-Clock circuit
packs in the PN. See the How to replace Tone-Clock circuit packs
section of ‘‘TDM-CLK (TDM Bus Clock)’’ on page 8-1604 Maintenance
documentation.
4. Enter display errors and follow the associated repair procedures for any
SNC-BD (if applicable to this fiber link configuration) or TDM-BUS errors.
5. Perform the ‘‘Fault Isolation for Fiber Links’’ on page 4-19, described in
Chapter 5.
6. If the test continues to abort, follow normal escalation procedures.
PASS The EI circuit pack(s) have detected the valid framing signal on the fiber.
1. Refer to errors from other EI circuit packs, SNI (SNI) tests, or DS1
Converter tests (if present) if the link is still not functioning.
Table 8-325. Test #238 Expansion Interface Fiber Out-of-Frame Query Test
Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page

Table of Contents

Other manuals for Avaya S8700