Maintenance-Object Repair Procedures
555-233-143
8-854 Issue 1 May 2002
207 FAIL The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 7. (The list fiber-link command displays a fiber links endpoints.)
1. Perform the ‘‘Fault Isolation for Fiber Links’’ on page 4-19. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1281, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1281, replace the
SNI in slot 7.
208 FAIL The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 8. (The list fiber-link command displays a fiber links endpoints.)
1. Perform the ‘‘Fault Isolation for Fiber Links’’ on page 4-19. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1537, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1537, replace the
SNI in slot 8.
209 FAIL The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 9. (The list fiber-link command displays a fiber links endpoints.)
1. Perform the ‘‘Fault Isolation for Fiber Links’’ on page 4-19. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1793, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1793, replace the
SNI in slot 9.
Table 8-328. Test #759 Configuration Audit Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page