Maintenance-Object Repair Procedures
555-233-143
8-856 Issue 1 May 2002
215 FAIL The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 15. (The list fiber-link command displays a fiber link’s endpoints.)
1. Perform the ‘‘Fault Isolation for Fiber Links’’ on page 4-19. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2561, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 2561, replace the
SNI in slot 15.
216 FAIL The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 16. (The list fiber-link command displays a fiber link’s endpoints.)
1. Perform the ‘‘Fault Isolation for Fiber Links’’ on page 4-19. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 2817, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 2817, replace the
SNI in slot 16.
217 FAIL The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 17. (The list fiber-link command displays a fiber link’s endpoints.)
1. Perform the ‘‘Fault Isolation for Fiber Links’’ on page 4-19. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3073, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 3073, replace the
SNI in slot 17.
Table 8-328. Test #759 Configuration Audit — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page