Maintenance-Object Repair Procedures
555-233-143
8-884 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. A Major or a Minor alarm may be logged with this error. A Major alarm is
raised when the total number of GPTD ports currently in service is less
than or equal to 1/2 of the threshold number administered via the change
system-parameters maintenance command. Otherwise, a Minor alarm is
raised. In either case, run the short test sequence on the alarmed GPTD
port and follow procedures for the individual test results.
b. The GPTD port lost its translation. Testing the GPTD port is sufficient to
reload its translation. If testing the GPTD port does not clear the error, then
replace the Tone Detector circuit pack containing the defective GPTD port.
c. This error indicates the GPTD port is having problems detecting
call-progress tones. If this error is logged constantly, replace the Tone
Detector circuit pack containing the defective GPTD port.
d. This Error Type indicates that the circuit pack has been removed or has
been insane for at least 11 minutes. To clear the error, reinsert or replace
the circuit pack.
Table 8-336. General-Purpose Tone Detector Port (CPTR) Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 17664 Tone Detector Audit/
Update test (#43)
MAJOR
MINOR (a)
ON test port UUCSSpp r 2
18 0 busyout port UUCSSpp WARNING ON release port UUCSSpp
130 (d) None WARNING ON test port UUCSSpp sh r 2
257 (b) 17666 Tone Detector Audit/
Update test (#43)
MAJOR
MINOR (a)
ON test port UUCSSpp r 3
513 (c) Any Tone Detection
Verification test (#42)
MAJOR
MINOR (a)
ON test port UUCSSpp r 3