Maintenance-Object Repair Procedures
555-233-143
8-892 Issue 1 May 2002
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
CLAN Ethernet Status
test (#1386), you may also clear errors generated from
other tests in the testing sequence.
CLAN Ethernet Status Test (#1386)
This test is nondestructive.
This test checks the status of the C-LAN ethernet port that originated this
signaling group. If the C-LAN ethernet port is in service, the test passes; if it is
OOS (out of service), the test fails.
NOTE:
Failure of this test will put the SIG-GRP in the OOS state.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
CLAN Ethernet Status test (#1386) X X ND
MedPro Status test (#1392) X X ND
H.323 Signaling Group Ping test (#1387) X X ND
Table 8-341. Test #1386 CLAN Ethernet Status Test
Error
Code
Tes t
Result Description / Recommendation
1125 ABORT Ethernet Link is not in service.
1. Check if the ethernet link is in service or not. If the link is not in service,
release the link using release link n or the release port UUCSSpp
command and repeat the test. This is a normal abort.
2. If the test continues to abort after following the repair procedures, escalate
the problem.
Continued on next page