HYB-LINE (Hybrid Line)
Issue 1 May 2002
8-913555-233-143
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until it is
idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t for the port).
2. If either list config or display port indicate that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT The system could not allocate a tone generator for the test.
1. Resolve any TONE-PT errors.
2. If no TONE-PT errors appear in the Error Log, retry the test at 1-minute
intervals up to 5 times.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
7 FAIL Conference test failed. User may be able to use conference circuit without
difficulty in some cases. In other extreme cases, conference calling will be
totally restricted.
The failure may be due to off-board circumstances, the most common of which
is an off-hook occurring during the test. Also, check the error logs against the
GPTD-BD, the TONE-BD, and the TONE-PT.
1. This error can be caused by a disconnected terminal. First, ensure that the
terminal is connected and the wiring is OK.
2. Then, issue the display port and status station commands to determine
whether the station is idle. If so, issue the test port command for this port.
3. If test continues to fail, issue the busyout port and the release port
commands, and then retest the port.
4. It is possible that the port may still be functional from a user’s point of view.
Table 8-352. Test #57 Hybrid Circuit and Conference Circuit Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page