HYB-LINE (Hybrid Line)
Issue 1 May 2002
8-915555-233-143
Hybrid Line Local Digital Loop-Around Test (#58)
This test checks the control channel between the media server and the ports
digital circuitry. The media server sends transparent data to the on-board
microprocessor and compares the data echoed back. This test is repeated three
times.
Table 8-353. Test #58 Hybrid Line Local Digital Loop-Around Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until it is
idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until it is
idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1, 2, 3 FAIL The control channel between the processor and the port is not transmitting
properly. This port is not operable.
1. Retry the test.
2. If the failure still occurs, issue the busyout and the release busy
commands, and then retest.
3. If the failure is occurring on more than one port on the board, suspect the
board.
4. If the failure is occurring on several boards in the same carrier, escalate the
problem.
5. If the failure appears to be isolated to one port, check all wiring to the set
and all set connections.
6. Replace the circuit pack as a last resort.
Continued on next page