HYB-LINE (Hybrid Line)
Issue 1 May 2002
8-921555-233-143
Hybrid Line Audits Test (#61)
This is a series of three tests that are classified as audits. These audits will abort
if attempted on an out-of-service station. The tests are as follows:
■ Switchhook Audit — This updates the media server’s records according to
the circuit packs’ records.
■ Bad Scan Inquiry — An up-link message is sent containing a count
generated due to certain events relating to the data link’s conditions. This
indicates data-transmission problems between the Hybrid circuit pack and
the voice terminal.
■ EPF Inquiry — An up-link status message of the Electronic Power Feed is
sent. Possible conditions are: EPF-on-ok, EPF-off, EPF-no-load, and
EPF-on-overcurrent.
Table 8-356. Test #61 Hybrid Line Audits Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error
1 ABORT The test was aborted due to an internal system error during the switchhook
audit.
2 ABORT Internal system error occurred during bad scan inquiry audit.
1. Make sure that the station is not in an out of service state.
2. Retry the command at 1-minute intervals up to 5 times.
3 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
Error Type is present, release the port via the release station extension
command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp to determine the station extension
number of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
Continued on next page