Loading...
LOG-SVN (Login Security Violation)
Issue 1 May 2002
8-1023555-233-143
Error Log Entries and Test to Clear Values
General Information about log-svn error log entries:
a. The number (115), that appears in the error type field, corresponds to the
location of the login in the internal login data structure.
b. The Alt Name field on the alarm report indicates the login ID associated
with the security violation and major alarm.
c. These errors/alarms are associated with a number of failed attempts to
access the system management/maintenance interface using an Avaya
services login ID that meet or exceed the customer administered threshold
parameters. The associated alarm is immediately raised as a major alarm.
d. The affected login ID will be disabled as a result of detection of the security
violation, unless it is the systems last enabled INADS-type login. The
provision to disable a login ID following detection of a security violation
involving that login ID is administrable on a login ID basis.
e. The enable login command is used to both enable a login that has been
disabled, and to retire any login security violation alarms associated with
the login ID.
f. Use of the enable login command to enable a login and/or retire alarms
must be executed using a login ID with greater service level hierarchy
permissions.
g. Access to the enable login command is controlled through the Administer
Permissions field on the Command Permission Categories form. This field
(Administer Permissions) must be set to y to access the enable login
command.
h. The Port alarm report field will set to the port where the final invalid login
attempt, involving the alarmed login ID, was detected. Valid port values for
G3i products include:
MGR1 Dedicated Manager 1 or G3 MT (management terminal)
connection
NET-n Network controllers dial-up port
INADS Alarm receivers port
EPN EPNs maintenance EIA port
EIA Other EIA port
Table 8-404. Security Violation Notification Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1-15 None None Major OFF enable login login-ID