MAINT (PNs Maintenance Circuit Pack)
Issue 1 May 2002
8-1037555-233-143
Battery Holdover Hardware
Verification Test (#311)
The hardware/firmware vintage of the PNs TN775D Maintenance boards does
not support battery holdover for all carriers. This test checks to see if PN cabinet
battery holdover for all carriers has been administered in error. If battery
holdover is administered for all carriers, the test will fail and a WARNING alarm
will be raised against this MO.
Table 8-411. TEST #303 PN Maintenance Circuit Pack Sanity Maze Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test was not received within the allowable time period.
2029 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The hardware vintage of the PNs Maintenance circuit pack does not support
battery holdover for all carriers.
NOTE:
This failure indicates that the cabinet administration is set for battery
holdover for all carriers.
1. Verify cabinet administration, make sure that the battery holdover feature is
administered correctly (That cabinet administration is not set for battery
holdover for all carriers.).
2. Retry the command at 1-minute intervals up to 5 times.
PASS The cabinet administration shows battery holdover for A carrier only. Also, the
hardware vintage of the PNs TN775D Maintenance board is correct.