MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 May 2002
8-1049555-233-143
3. At the command prompt, type ping 10.32.64.97 (the internal IP trunk
servers address), and press
Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
and 6 in Figure 8-58) have not worked loose.
b. Otherwise, replace the circuit pack.
4. At the command prompt, type ping 10.32.64.96 (the IP address of the
internal Motorola MPC860 processor), and press
Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
and 6 in Figure 8-58) have not worked loose.
b. Otherwise, replace the circuit pack.
5. Ping the gateway: at the command prompt, type ping XX.XXX.XXX.XXX
(the IP address of the gateway), and press
Enter.
6. When finished, type exit at the command prompt, and press
Enter.