MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 May 2002
8-1055555-233-143
Notes:
a. Error Type 1—Indicates that the circuit pack has totally stopped
functioning or is not fully administered. The alarm is logged about 15
minutes after the circuit pack has been removed or 11 minutes after the
SAKI test (#53) fails.
To be fully administered, a MAPD circuit pack must meet all of these
conditions:
■ Have an entry in the circuit plan (change circuit pack)
■ Be administered (add ds1 UUCSS)
■ Be physically inserted into the correct slot
3073 to
3160
(m)
Any Slip Alarm Inquiry test
(#144)
MIN/
WRN
3
OFF test board UUCSS r 6
3330 (n) 46083 MIN/
WRN
3
ON
3585 to
3601 (o)
Any Misframe Alarm Inquiry
test (#145)
MIN/
WRN
3
OFF test board UUCSS r 6
3840 (p) Any None
3841 (q) 4358
3842 (r) 46097
3843 (s) 46081
3999 (t) Any None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit pack,
then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a period of 15
minutes. Warning alarms are also raised against any ports administered on the circuit pack.
3. Major alarms on this MO may be downgraded to minor or warning alarms based on values set in the set options
command.
Table 8-419. MAPD (TN802) Error Log entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page