Maintenance-Object Repair Procedures
555-233-143
8-1058 Issue 1 May 2002
k. Error Type 1537LAN Bus Timeout; the circuit pack transmitted too many
bytes on the LAN bus for a single frame. This condition may be caused by:
an on-board fault
faulty data received on one of the circuit packs external ports. If
any of the ports on this circuit pack are alarmed, refer to the repair
procedures for those MOs.
If the error occurs 3 times within 10 minutes, the system raises the board
alarm and isolates it from the packet bus.
1. Clear the alarm and restore the board to the packet bus using the
following command sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS long clear
d. release board UUCSS
2. If the problem persists, and there are no PKT-BUS alarms or port
alarms, then replace the circuit pack. See ‘‘Shutting Down NT on
the TN802’’ before removing the circuit pack.
l. Error Type 1538Hyperactive circuit pack is out-of-service and may
exhibit one or more of the following symptoms:
The common circuit pack tests (for example, Test #50 and/or Test
#52) abort with Error Code 2000.
Port tests on this circuit pack return NO-BOARD.
A busyout/release of the circuit pack has no effect on test results.
A list configuration command shows that the circuit pack and ports
are properly installed.
The circuit pack is isolated from the system, and every trunk or port on this
circuit pack is placed into the out-of-service state. The system attempts to
restore the circuit pack within 20 30 minutes. When no faults are
detected for 20 30 minutes, the MAPD Interface circuit pack is restored to
normal operation, and every trunk or port on the MAPD Interface circuit
pack returns to the in-service state.
1. If the board is not restored to normal operation or the error recurs
after the board is restored to normal operation, escalate the
problem.
m. Error Type 3073 3160Board is reporting slip errors. Aux Data shows
the last reported slip count.