Maintenance-Object Repair Procedures
555-233-143
8-1076 Issue 1 May 2002
IP Address Query Test #1371
This test is destructive.
The Media Processor has two interfaces for configuring the board: through the
NT PC interface, and the SAT via CCMS messages. For R10 DoLAN, the SAT via
CCMS is the only approved interface. However, the NT PC interface cannot
easily be disabled. It is possible that changes can be made via the NT PC
interface that cause the Media Processor board to be inconsistent with S8700
Multi-Connect translations. The area of concern is the IP address, subnet mask,
and gateway translation.
This test sends the Media Processor the IP address, subnet mask, and gateway
translation (IP parameters). If the parameters do not match S8700 Multi-Connect
translations, the new values are written into the Windows registry, and the NT PC
asks the maintenance sub-system to reboot the board. The board goes through a
physical board removal and insertion.
When this test fails, it is an indication that an illegal change was made and the
customer should be notified. Also, writing the IP address parameters to the
registry requires NT to reboot. If the IP addresses match, there is no need to
update the registry and reboot NT.
Table 8-438. Test #1371 IP Address Query Test
Error
Code
Te s t
Result Description / Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Insufficient system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2801 ABORT Unable to find IP address data for this location. Verify that the board is
administered.
2807 ABORT The board is administered, but not enabled in the change ip-interfaces form.
FAIL The IP address, subnet mask, and gateway translation parameters do not
match S8700 Multi-Connect translations. After the new values are written
into the Windows registry, the NT PC must go through a reboot. The board
goes through a physical board removal and insertion.
1. If the problem persists, replace the circuit pack.
PASS Translation data matches the Windows Registry.