Maintenance-Object Repair Procedures
555-233-143
8-1080 Issue 1 May 2002
NIC Query Test (#1383)
This test is nondestructive.
This test passes if the Ethernet port is connected, and you can talk on the
network. Otherwise, it fails with no fail code or AUX data.
Table 8-441. Test #1383 NIC Query Test
Error
Code
Tes t
Result Description / Recommendation
None ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the command again.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The Ethernet port is not connected, and you cannot talk on the network.
PASS The Ethernet port is connected, and you can talk on the network.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the MedPro
interface if it is not already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board re-initializes it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and the port.
Continued on next page