EasyManua.ls Logo

Avaya S8700 - Page 1806

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance-Object Repair Procedures
555-233-143
8-1084 Issue 1 May 2002
Table 8-444. DSP Capacity Query Test (#1382)
Error
Code
Te s t
Result Description / Recommendation
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1-11 FAIL Some DSPs on the circuit pack have failed. The FAIL code is the number of
bad DSPs reported (TN802B only).
FAIL For the TN2302 only, the DSP failed. If it continues to fail, it will be taken out
of service.
PASS All 11 DSPs are functioning and in-service.
0NO
BOARD
No board was detected by the test.
1. Check the Error Log for wrong board (Error Type 125) or no board (Error
Type 131). Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity. If hyperactive, use the reset board UUCSS command.
3. Run the test again. If it fails, the circuit pack may be bad. Replace the
circuit pack and retest.
Continued on next page