MEDPROPT (TN802/TN2302 MED PRO DSP PORT)
Issue 1 May 2002
8-1087555-233-143
Port Status Query Test (#1407)
This test is nondestructive
This test queries the Port status.
Table 8-446. port Status Query Test (#1407)
Error
Code
Test
Result Description / Recommendation
1 ABORT This port is Out of service (OOS) due to:
A board-level problem, for example no IP address has been translated for
this location.
A DSP hardware problem (See ‘‘TDM NIC Loop-Around Test (#1380)’’
and ‘‘DSP Capacity Query Test (#1382)’’.
2 ABORT This port has been made maintenance busy
1002 ABORT The system could not allocate timeslots for the test. The system may be
under heavy traffic conditions, or it may have timeslots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
2. If the system has TDM-BUS errors, clear any errors, and retry the
command at 1-minute intervals up to 3 times.
3. If the command continues to abort, escalate the problem.
2000 ABORT Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
FAIL Unable to get status for this port. Verify that this board has been
administered correctly, and that there are no alarms against this board.
PASS The board is functioning properly and the port is in-service and available.
0NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues, if
applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, replace the board and retest.
Continued on next page