MET-LINE (MET Line)
Issue 1 May 2002
8-1101555-233-143
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2012 ABORT Internal system error.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 8-452. Test #57 Hybrid Circuit and Conference Circuit Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page