MET-LINE (MET Line)
Issue 1 May 2002
8-1103555-233-143
PASS Hybrid Circuit and Conference Circuit test passed. The hybrid circuitry is
transmitting properly.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to
ensure that there is a valid board inserted.