Maintenance-Object Repair Procedures
555-233-143
8-1108 Issue 1 May 2002
MET Line Ringer Update Test (#62)
In this update, a “ringer on” or a “ringer off” message is sent to the firmware to
start and stop the ringer on the set.
Table 8-455. Test #62 MET Line Ringer Update Test
Error
Code
Tes t
Result Description / Recommendation
3 ABORT This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
present, release the port via release station extension and run the test
again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use display port UUCSSpp to determine the station extension of the port.
Use status station to determine the service state of the port. If the port is
in use, wait until the port is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Hybrid Station Ringer Update passed.
1. If complaints persist, investigate using other circuit pack tests, and by
examining the terminal, wiring, and connections.
0NO
BOARD
The test could not relate the internal ID to the port. This could be due to
incorrect translations, no board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, check to
ensure that there is a valid board inserted.