MMI-BD
Issue 1 May 2002
8-1113555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. The circuit pack stopped functioning or it was physically removed from the
system. The alarm logs approximately 11 minutes after the circuit pack has
been removed and/or the SAKI Sanity test (#53) fails.
If the circuit pack is in the system and the red LED is on, follow the
instructions for a red alarm in ‘‘Circuit Pack LEDs’’ in Chapter 6, ‘‘LED
Interpretation’’. Also, see Handling Common Port Circuit Packs.
b. This circuit pack has been busied out using the busyout board UUCSS
command.
c. There are more than four MMI circuit packs in the system. Remove the
circuit pack that generated the error in the error log by locating the slot
indicated by the error.
Table 8-457. MMI-BD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test board UUCSS sh r 1
1 (a) Any None MINOR ON
18 (b) 0 Busyout board UUCSS WARNING OFF release board UUCSS
217 (c) 0 None WARNING ON
257 (d) 65535 Control Channel Loop
test (#52)
MINOR ON test board UUCSS r 3
513 (e) 4352
to
4357
Uplink error from pack
769 (f) Any MMI Synchronization
Status test (#1123)
1281 (g) Any Circuit Pack Restart test
(#594)
MAJOR ON
1538 (h) Any Software detected error MINOR ON
1793 (i) ANY TSI XTalk (#6) MINOR ON test board UUCSS l r 3
2049 (j) Any TSI Loop (#1108) MAJOR ON test board UUCSS l r 3