Maintenance-Object Repair Procedures
555-233-143
8-1116 Issue 1 May 2002
Table 8-459. Test #6 TSI Crosstalk Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test, the traffic load on the
system is very high, or the time slots are out-of-service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone detector for the test. The system is
oversized for the number of tone detectors present, or some tone detectors are
out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
2000 ABORT Response to the test was not received from the MMI-BD circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
ports are idle. Reset the circuit pack by issuing the busyout board PCSS,
reset board UUCSS, followed by the release board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error. This is an abnormal abort.
2100 ABORT Could not allocate the necessary resources to run this test. This is an
abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The TSI was found to be transmitting in error. This causes noisy and unreliable
connections.
1. Replace the circuit pack.
PASS The TSI is correctly using its allocated time slots.
Continued on next page