MMI-BD
Issue 1 May 2002
8-1119555-233-143
Control Channel Loop-Around Test (#52)
Refer to the repair procedure described in XXX-BD (Common Port Circuit Pack)
maintenance documentation as ‘‘Control Channel Loop-Around Test (#52)’’ on
page 8-1555.
SAKI Sanity Test (#53)
Refer to the repair procedure described in the XXX-BD (Common Port Circuit
Pack) maintenance documentation as ‘‘SAKI Sanity Test (#53)’’ on page 8-1555.
FAIL The MMI circuit pack is out of MMI synchronization. Run the long option of the
test board command.
1. Wait up to 5 minutes, and then reset the circuit pack with these commands:
busyout board UUCSS, then reset board UUCSS, followed by release
board UUCSS.
2. Rerun the test; if the same result occurs again, replace the circuit pack.
1100 PASS The MMI circuit pack is providing the synchronization correctly. This MMI
circuit pack is designated as the Master Sync source.
1101 PASS The MMI circuit pack is listening to the synchronization signal correctly.
Table 8-461. Test #1122/1123 MMI Synchronization Status Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page