Maintenance-Object Repair Procedures
555-233-143
8-1148 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error code appears in the Error Log only if the MTB circuit pack has
been removed since the Error Log was last cleared. Verify that the circuit
pack has been reinserted.
b. This error indicates a hardware failure on the Analog Port circuitry.
Replace the Maintenance/Test circuit pack if the above command does not
resolve the alarm.
c. This error indicates that call processing records did not agree with
on-board records for the hook state (on-/off-hook) of the Maintenance/Test
analog port. This error is not service-affecting and no action is required.
Table 8-471. M/T-ANL Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
(a)
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any Any Anytest port UUCSSpp
1 (b) 41018 none MINOR ON test port UUCSSpp l r 3
18 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
257 Any NPE Crosstalk test (#9) MINOR ON test port UUCSSpp l r 3
513 Any Analog Port Sanity test
(#963)
MINOR ON test port UUCSS01 r 2
769 Any Analog Port Digital
Loop-around test (#13)
MINOR ON test port UUCSSpp r 3
3840(c) Any Hook State Inquiry test
(#566)