Maintenance-Object Repair Procedures
555-233-143
8-1158 Issue 1 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. This error indicates that the circuit pack has stopped functioning. Reset the
circuit pack via busyout board UUCSS, reset board UUCSS, and release
board UUCSS commands. If the SAKI Sanity test (#53) passes, then the
on-board circuitry is healthy. If the SAKI Sanity test (#53) fails, replace the
circuit pack.
b. The circuit pack has been busied out via the busyout board UUCSS
command. Execute release board UUCSS command.
c. A port processor on the circuit pack failed to initialize. Reset the circuit
pack via busyout board UUCSS, reset board UUCSS, and release
board UUCSS. if the problem does not go away, replace the circuit pack.
Maintenance/Test Board Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
1
1. Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values used in
the set options command.
On/Off
Board Test to Clear Value
0
2
2. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any Any Anytest port UUCSSpp sh r 1
1(a) 0 SAKI Sanity test (#53) MINOR ON See footnote a
18(b) 0 busyout board WARNING OFF release board UUCSS
36(c) 0
217(e) WARNING ON
257(d) 0 CC Loop test (#52) MINOR ON test board UUCSS r3
267(e) WARNING ON
513(f) 4352
to
4357
769(g) 4358
1025(h) 4363 NPE Audit test (#50) test board UUCSS l
1538(i) 0 MINOR ON
3840(j) 4096
to
4101
3999 (k) Any None