M/T-DIG (Maintenance/Test Digital Port)
Issue 1 May 2002
8-1163555-233-143
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. This error indicates a hardware failure on a digital port’s circuitry. Replace
the Maintenance/Test circuit pack if the alarm is not resolved by the
command above.
b. The port has been busied out via the busyout port UUCSSpp command.
c. This error indicates that Maintenance/Test digital port is talking on more
than just its assigned time slot. Replace the Maintenance/Test circuit pack.
d. This error indicates that the Maintenance/Test digital port has failed its
self-test. Since the Digital Port Sanity test runs only on port 2, but tests
both ports 2 and 3, both ports will be alarmed when the test fails. Note that
the command above indicates to test port 2, even if the error is logged
against port 3.
e. This error indicates that the Maintenance/Test digital port has been unable
to successfully loop data from a tone generator to a tone detector.
f. This error indicated that call processing records did not agree with
on-board records for the hook state (on-/off-hook) of the Maintenance/Test
digital port. This error is not service-affecting and no action is required.
M/T-DIG Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any Any Anytest port UUCSSpp
1 (a) 41018 none MINOR ON test port UUCSSpp l r 3
18 (b) 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
257 (c) Any NPE Crosstalk test (#9) MINOR ON test port UUCSSpp l r 3
513 (d) Any Digital Port Sanity test
(#565)
MINOR ON test port UUCSS02 r 2
769 (e) Any Digital Port Loop Around
test (#13)
MINOR ON test port UUCSSpp r 3
3840 (f) Any Hook State Inquiry test
(#566)